Spooldown Airstart

The spooldown airstart can be attemped immediately after engine loss before significant spooldown has occured. This is the fastest way to restart an engine.

Depending on engine RPM it might take up to 10 seconds to notice any RPM increase and up to 90 seconds to reach commanded RPM. If the engine mode selected by the AFTC was PRI, a renewed attempt may be made in SEC.

Throttle

IDLE or above

If no relight occurs

N/A

Throttle

OFF then IDLE

If still no relight

N/A

ENG MODE SELECT switch

SEC

Throttle

If no start after mode switch, OFF then IDLE

After successful airstart in SEC

N/A

ENG MODE SELECT switch

PRI if possible